Merilyzer ClotQuant 2
Coagulation Analyzer
Machines & equipment
Meril Merilyzer ClotQuant 2 semi auto coagulometer is designed for PT and APTT analysis, supporting routine coagulation testing in labs.
01 / A CLOSER LOOK
Features that
define the product.
- 2 Testing channels, 16 Sample pre-warming positions and 4 Reagent pre-warming positions
- ClotQuant 2 is equipped with Electronically-linked pipette to reduce manual errors, built-in thermal printer and on-board stop watch
- In Sample run, high and low flags will be displayed and printed in run receipt, based on reference range entered by user
- In QC run, based on mean and SD values entered by user, SD flags (+1, +2, +3,-1, -2,-3), over and under will be displayed and printed in QC run receipt
- QC Levey Jennings to track performance of controls (Low, Medium and High) for 30 days. 40 tests can be stored for each level of control i.e. total 120 results
- ClotQuant 2 ensures accurate results by monitoring the exact Sample Incubation Time. Temperature does not exceed above or below the user defined limits
- ClotQuant 2 detector channels can be aligned in any positions to ensure operators convenience
02 / HOW IT WORKS
The technology.
Measuring Principle - Advanced scattered light
03 / TECHNICAL DETAILS
Specifications.
| Category | Specification |
|---|---|
| Measuring Principle | Advanced scattered light |
| Reagent Type | Open |
| Reagent Consumption | < 50 μL |
| Tests Performed | PT, APTT, TT, Fibrinogen, and clotting factors |
| Test Wavelength | 470 nm |
| Testing Channels | 2 channel (ClotQuant 2), 4 channel (ClotQuant 4) |
| Sample Pre-warming Positions | 16 positions (ClotQuant 2), 24 positions (ClotQuant 4) |
| Reagent Pre-warming Positions | 4 positions (ClotQuant 2), 6 positions (ClotQuant 4) |
| Dispense Precision | CV < 2% |
| Temperature Control Precision | 37 ± 0.3°C |
| Repeatability | Activated partial thromboplastin time tolerance ± 2 s |
| Stability | Activated partial thromboplastin time tolerance within one hour ± 2 s |
| Channel Consistency | Each channel activated partial thromboplastin time tolerance ± 2 s |
| Linearity Error | Fibrinogen concentration linear correlation r² > 0.98 |
| Memory | 5000 test results (500 Patient ID, 10 tests for each ID) |
| Power Supply | 230 VAC ± 10%, 50Hz |
| Communication Interface | RS232 interface, PC connecting |
| Printer | Built-in thermal printer, 57 mm paper width |
| Report | Date and ID wise |
| Work Environment | 15°C - 30°C |
| Humidity | ≤ 90% |
| Dimensions (L × W × H) | 400 mm × 274 mm × 350 mm |
| Weight | Approx. 10 kgs |